The instrument allows measuring the following parameters for the transformers of all the circuits and groups of connections according to GOST 30830 - Transformation rate;
- No-load operation loss at the low voltage;
- Short circuit impedance;
- Voltage and current
- Power factor;
- Measured current (voltage) frequency;
- Phase displacement angle between the voltage and current.
- Effective (root-mean-square) voltage.
It is manufactured in two hardware versions:
- Standard (operating temperature range: from 5 °C to 40 °C);
- North (operating temperature range: from minus 15 °C to 55 °C).
Technical Characteristics | |||
---|---|---|---|
Measured quantity | Designation | Measurement range | Measurement error, % ± |
Alternating voltage root-mean-square value (UBH channels, phases A, B,C), V |
UВН |
50-500 |
0.25 (nominal) |
Alternating voltage root-mean-square value (UHH channels, phases A, B,C), V |
UНН1 |
0,5-5 |
|
UНН2 |
5-50 |
||
UНН3 |
50-500 |
||
Transformation rate |
КТ1 |
UВН/ Uнн1 |
0.5 (nominal) |
КТ2 |
UВН/ Uнн2 |
||
КТ3 |
UВН/ Uнн3 |
||
Alternating current root-mean-square value (I channels, phases A, B,C), A |
I1 |
0,02-0,2 |
0.25 (nominal) |
I2 |
0,20-2 |
||
I3 |
2-20 |
||
I4 |
20-200 |
1.0 (nominal) |
|
I5 |
200-2000 |
0.5 (nominal) |
|
No-load operation loss at the low voltage (active electric power) (COS(1) D1.0), W |
P11 |
4,4-44 |
0.25 (nominal) |
P21 |
44-440 |
||
P31 |
440-4400 |
||
No-load operation loss at the low voltage (active electric power) (COS(1) D0.5), W |
P12 |
2,2-22 |
1.0 (nominal) |
P22 |
22-220 |
||
P32 |
220-2200 |
||
Short circuit impedance, O |
Zкз1 |
1100-11000 |
0.5 (nominal) |
Zкз2 |
110-1100 |
||
Zкз3 |
11-110 |
||
Zкз4 |
1,1-11 |
1.5 (nominal) |
|
Zкз5 |
0,11-1 |
1.0 (nominal) |
|
Power factor |
λ |
from -1.0 to +1.0 |
0.05 (absolute) |
Alternating current frequency, Hz |
f |
from 45 to 65 |
0.05 (absolute) |
Phase displacement angle between the voltage and current, ° |
Δϕ |
from -180° to +180° |
0.25 (absolute) |
Дополнительно с прибором могут поставляться:
3 датчика тока 200 А | |
---|---|
![]() |
Каждый конкретный прибор калибруется с тремя конкретными датчиками тока 200А (токовые клещи). |
комплект из 14 измерительных кабелей | ||||
---|---|---|---|---|
Комплект измерительных кабелей | Длина, м | Трубка из ПХВ | Трубка из силикона | Вариант исполнения |
![]() |
2 |
+ |
1 |
|
+ |
9 |
|||
5 |
+ |
3 |
||
+ |
10 |
|||
10 |
+ |
5 |
||
+ |
11 |
|||
15 |
+ |
7 |
||
+ |
12 |
3 датчика тока 2000 А (катушка Роговского) | |
---|---|
Конкретный прибор калибруется 3 конкретными датчиками тока 2000А (катушкой Роговского). Гибкие датчики позволяют провести измерение тока на токоведущем отводе диаметром до 20 см. Длина кабеля подключения датчика к прибору не менее 2,5 м. |